|
Excelitas corp
camera configurations Camera Configurations, supplied by Excelitas corp, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm40358496-88-11-13?v=Excelitas+corp Average 96 stars, based on 1 article reviews
camera configurations - by Bioz Stars,
2026-07
96/100 stars
|
Buy from Supplier |
|
Basler
camera aca720 520uc Camera Aca720 520uc, supplied by Basler, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm41254412-202-5-2?v=Basler Average 93 stars, based on 1 article reviews
camera aca720 520uc - by Bioz Stars,
2026-07
93/100 stars
|
Buy from Supplier |
|
IMASEN Engineering Corporation
2d imasen camera configuration 2d Imasen Camera Configuration, supplied by IMASEN Engineering Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm40006304-92-1-2?v=IMASEN+Engineering+Corporation Average 90 stars, based on 1 article reviews
2d imasen camera configuration - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Canon inc
dslr camera with an ef-s 18–55 f/3.5–5.6 iii lens configuration Dslr Camera With An Ef S 18–55 F/3.5–5.6 Iii Lens Configuration, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm38932632-79-30-20?v=Canon+inc Average 90 stars, based on 1 article reviews
dslr camera with an ef-s 18–55 f/3.5–5.6 iii lens configuration - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Danaher Inc
ring configurated czt camera starguide Ring Configurated Czt Camera Starguide, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm37592454-3-29-34?v=Danaher+Inc Average 86 stars, based on 1 article reviews
ring configurated czt camera starguide - by Bioz Stars,
2026-07
86/100 stars
|
Buy from Supplier |
|
Hamamatsu
streak camera configuration c10910 Streak Camera Configuration C10910, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm38054790-206-9-13?v=Hamamatsu Average 90 stars, based on 1 article reviews
streak camera configuration c10910 - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Hamamatsu
base configuration hamamatsu fusion bt scmos camera ![]() Base Configuration Hamamatsu Fusion Bt Scmos Camera, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/bio_rxiv__2023__10__23__563122-2548-8-10?v=Hamamatsu Average 90 stars, based on 1 article reviews
base configuration hamamatsu fusion bt scmos camera - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
CONOSTAN
libs instrument configured with a compact czerny-turner spectrometer and iccd camera ![]() Libs Instrument Configured With A Compact Czerny Turner Spectrometer And Iccd Camera, supplied by CONOSTAN, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/us11768157-692-30-11?v=CONOSTAN Average 90 stars, based on 1 article reviews
libs instrument configured with a compact czerny-turner spectrometer and iccd camera - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
NanoSight ltd
high-sensitivity scmos camera configured with the nanosight ns300 system ![]() High Sensitivity Scmos Camera Configured With The Nanosight Ns300 System, supplied by NanoSight ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm34852710-49-15-14?v=NanoSight+ltd Average 90 stars, based on 1 article reviews
high-sensitivity scmos camera configured with the nanosight ns300 system - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
|
Specim Spectral Imaging
line-scanning push-broom-configured camera vlnircl-100-n173 ![]() Line Scanning Push Broom Configured Camera Vlnircl 100 N173, supplied by Specim Spectral Imaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/camera+configuration/pm34303815-134-8-10?v=Specim+Spectral+Imaging Average 90 stars, based on 1 article reviews
line-scanning push-broom-configured camera vlnircl-100-n173 - by Bioz Stars,
2026-07
90/100 stars
|
Buy from Supplier |
Journal: bioRxiv
Article Title: Automated 3D multi-color single-molecule localization microscopy
doi: 10.1101/2023.10.23.563122
Figure Lengend Snippet: A) Single-mode illumination path(s) (blue): The single-mode laser(s) are spatially filtered, expanded and homogenized. The resulting flat-top intensity profile is further expanded by exchangeable telescopes to control the size of the illumination field. Setting the angle for TIRF/HILO illumination is accomplished by positioning of a motorized mirror. The laser power is monitored in real time by measuring the <1% transmission of the laser lines at the illumination dichroic mirror. Emission path (green): A primary image is produced by a tube lens, restricted in spatial extent by a slit and relayed in a 4f configuration via a spectrally discriminative image splitter to form two secondary images on an sCMOS camera. A variable astigmatic lens (cylindrical lens pair) can be removed/inserted for 2D/3D imaging, while a Bertrand lens allows viewing of the objective back focal plane. Focus lock path (red): The focus lock laser is separated from emitted fluorescence by the emission dichroic mirror, focused to the objective back focal plane and launched obliquely to return under the TIRF condition allowing axial drift of the coverslip relative to the objective lens to be measured via a quadrant photodiode and corrected via the control loop of the piezo flexure stage mounting the objective. B) For clarity the multi-mode laser illumination path (orange) has been shown separately but all modules are co-compatible. A magnified image of the tip of a square core multimode fiber (coupled to a multi-mode laser engine) is produced and re-imaged onto the sample via a tube lens in a retrofocus arrangement and the objective lens. The multi-mode laser is coupled into the microscope by translation of the motorized mirror (HILO/TIRF) fully out of the beam path
Article Snippet: The instructions provided assume the use of the
Techniques: Control, Transmission Assay, Produced, Imaging, Fluorescence, Microscopy
Journal: bioRxiv
Article Title: Automated 3D multi-color single-molecule localization microscopy
doi: 10.1101/2023.10.23.563122
Figure Lengend Snippet: Top: as viewed from the front/right of the microscope. From left-right: the tube lens, field aperture, first steering mirror, first relay lens, laser blocking filters, astigmatic lens and filter wheels either side of the image splitter dichroic mirror. Bottom: as viewed from the back/left of the microscope highlighting the image splitter platform. Following the filter wheel, the transmitted and reflected paths each comprise a second relay lens and steering mirror before the images are recombined by a knife-edge mirror (occluded in figure) and imaged onto an sCMOS camera.
Article Snippet: The instructions provided assume the use of the
Techniques: Microscopy, Blocking Assay